| FIM - 22/41 SPECIFICATIONS |
Frequency Range: FIM-22 FIM-41 |
200 kHz to 550 kHz 540 kHz to 5.0 MHz in two bands: Band "A" 0.54 MHz to 1.61 MHz Band "B" 1.58 MHz to 5.0 MHz |
| Field Intensity Range: |
10 uV per meter to 10 V per meter |
| Accuracy of Calibration: |
1%, referenced to NIST Standard field (Calibrated at 220 mV per meter) |
Accuracy of Range Attenuator: |
2% over entire FI range and tuning band |
Selectivity: FIM-22 Bandwidth (6 dB) Bandwidth (60 dB) IF Rejection Image Rejection
|
4 kHz nominal with multi-pole hybrid filter 10 kHz maximum 70 dB minimum; 40 dB minimum at 455 kHz 60 dB minimum |
Selectivity: FIM-41 Bandwidth (6 dB) Bandwidth (60 dB) IF Rejection Image Rejection
|
7 kHz nominal with multi-pole hybrid filter 15 kHz maximum 35 dB minimum 65 dB at 540 kHz decreasing to 45 dB (minimum) at 5.0 MHz |
| IF Frequency: |
455 kHz |
| Panel Meter: |
4" mirrored scale, logarithmic graduations 1 to 10, taut band meter movement, 3% linearity |
| Antenna: |
Shielded loop, integral part of hinged cover |
| Audio Outputs: |
Front Panel loudspeaker, weather treated cone Headphone jack, high and low Z (disconnects speaker) |
| Recorder Output: |
0.4 to 4 Vdc proportional to field intensity for each attenuator range, source resistance 2200 ohms |
| Lights: |
Frequency dial and meter; panel switch for night use |
| Batteries: 6 required |
Standard 1.5 V C-Zn "D" cells or 1.5 V Alkaline cells for extended life at very low temperatures |
| Battery Life: |
Greater than 1000 FI readings (reduced life with frequent use of lights and/or high speaker volume) |
| Ambient Temperature, F (C): |
Continuous exposure -10 deg. (23 deg.) to 130 deg. (54 deg.); "reading time" exposures practical at lower temperatures. |
| Dimensions. IN. (CM): |
Cover closed: 8.75 (22.2) H, 11.5 (29.2) W, 5.125 (13) D Cover open: 3.875 (9.8) D - (gripping width) |
| Weight, LB (KG): |
12.0 (5.5) with batteries |
External RF Input: FIM-22 FIM-41 |
200 kHz to 550 kHz, 10 uV to 10 V 540 kHz to 5.0 MHz, 10 uV to 10 V |
| RF Input Switch: |
Selects loops antenna (ANT) or panel connector (EXT) |
| Meter Switch: |
Selects normal linear (LIN) or logarithmic (LOG) operation |
| Logarithmic Dynamic Range: |
60 db compressed input range for FI meter and recorder input |